Regulation
145.A.10 — Scope
145.A.10 sets the scope of Section A of Part 145: as amended by Regulation (EU) 2021/1963, it establishes the requirements to be met by an organisation to…
Press the slash key anywhere on the page to jump to search. Use the arrow keys to move through results and Enter to open one.
Maintenance organisations: approval, staffing, procedures and records.
28 pages in Part-145. Type to filter them, or press Enter to search the whole hub.
Regulation
145.A.10 sets the scope of Section A of Part 145: as amended by Regulation (EU) 2021/1963, it establishes the requirements to be met by an organisation to…
Regulation
145.A.15 requires that an organisation seeking a Part 145 maintenance organisation approval must submit a formal application to the competent authority in a…
Regulation
145.A.20 establishes that a Part 145 approval is granted based on a defined scope of work, and the organisation may only perform maintenance within the…
Regulation
145.A.25 requires facilities appropriate for all planned work, including the specified base and component maintenance capacity, office accommodation, task…
Regulation
145.A.30 establishes requirements for the accountable manager, nominated persons, a maintenance man-hour plan for qualified staff and competency controls,…
Regulation
A certification authorisation permits the holder to sign certificates of release to service on the approved organisation’s behalf within the stated limitations.
Regulation
145.A.40 requires the organisation to have available and use the necessary equipment and tools to perform the approved scope of work, including ensuring…
Regulation
145.A.42 requires the organisation to establish procedures for the acceptance of components, standard parts and materials for installation to ensure that…
Regulation
145.A.45 requires the organisation to hold and use applicable current maintenance data which is necessary in the performance of maintenance, including…
Regulation
145.A.47 requires the organisation to have a production planning system appropriate to the amount and complexity of work, ensuring that all maintenance…
Regulation
145.A.48(a) allows maintenance only when all necessary facilities, equipment, tooling, material, maintenance data and personnel are available.
Regulation
Appropriately authorised certifying staff must issue the certificate of release to service (CRS) on behalf of the organisation when they have verified that…
Regulation
Under 145.A.55(a)(1), the organisation must record the details of maintenance carried out within the scope of its approval and retain, as a minimum, every…
Regulation
Report to the competent authority and to the organisation responsible for the design of the aircraft or component any safety-related event or condition of…
Regulation
145.A.65, as replaced by Regulation (EU) 2021/1963, requires the organisation to establish procedures which ensure that human factors and good maintenance…
Regulation
The organisation shall establish and maintain a maintenance organisation exposition (MOE) that includes, directly or by reference, all of the items listed…
Regulation
145.A.75 lists the privileges of a Part-145 organisation, exercised in accordance with the MOE: maintenance, subcontracting, maintenance at other locations,…
Regulation
Point 145.A.80 (Limitations on the organisation) was deleted from Annex II (Part-145) by Regulation (EU) 2021/1963 and is no longer an active requirement.
Regulation
145.A.85 requires prior formal approval by the competent authority for the changes it specifies and for every other Part-145 change requiring prior approval.
Regulation
145.A.90 makes validity conditional on compliance with Regulation (EU) 2018/1139 and its delegated and implementing acts, taking account of 145.B.350…
Regulation
After receiving a findings notification under 145.B.350, the organisation must identify the root causes and contributing factors, define a corrective action…
Regulation
145.A.200 requires the organisation to establish, implement and maintain a management system.
Answer
EASA Part-145 is the maintenance organisation approval standard in Commission Regulation (EU) No 1321/2014 for organisations that perform maintenance on…
Comparison
In aviation, QA focuses on whether the system and processes are controlled and compliant, while QC focuses on whether the maintenance output or product…
Comparison
For Part-145 and Part-CAMO, a level 1 finding concerns significant non-compliance which lowers safety or seriously endangers flight safety.
Guidance
Explores the relationship between Part 145 maintenance organisations, standalone CAMO organisations, and State ICAO obligations.
Guidance
Explains the key differences between Part M and Part 145 record-keeping requirements.
Guidance
The introduction of Part 145.A.37 and what it means for airworthiness review staff roles and responsibilities.
Course
3 courses · 1.5 days · Sofema Aviation Academy
Course
2.5 days · Voice Over · Sofema Aviation Academy
Course
2.5 days · Voice Over · Sofema Aviation Academy
Course
3 courses · 1.5 days · Sofema Aviation Academy
Course
0.2 days · Voice Over · Sofema Aviation Academy
Course
3 courses · 1.5 days · Sofema Aviation Academy