QA vs QC in aviation
Content updated
On this page
In aviation, QA focuses on whether the system and processes are controlled and compliant, while QC focuses on whether the maintenance output or product meets the required standard at the point it is checked.
What it means in practice
QA is process assurance. It includes compliance monitoring, procedure control, audit activity, systemic corrective action, management review, and checking whether the organisation’s processes are designed and working to produce compliant maintenance. QC is output control. It includes inspection, testing, verification, and direct checking of work, materials, and released products.
For a Part-145 maintenance organisation, the management system shall include a function to monitor the compliance of the organisation with the relevant requirements. A workshop can perform good end-item inspection and still fail if its procedures, competence control, records, or subcontractor controls are weak. Under 145.A.48(c)(1), the organisation shall ensure that after the completion of the maintenance, a general verification is carried out to ensure that the aircraft or component is clear of all tools, equipment and any extraneous parts or material, and that all access panels that were removed have been refitted.
Who it applies to
The distinction matters most for Part-145 maintenance organisations, CAMOs, and anyone managing compliance or internal oversight. Quality managers, compliance monitoring staff, supervisors, and certifying staff all need to understand whether they are checking the process, the output, or both.
The same organisation may use different internal titles, but for a Part-145 maintenance organisation the accountable manager shall nominate a person or group of persons with the responsibility to manage the compliance monitoring function as part of the management system. The person or group nominated for that function shall have a responsibility to the accountable manager and direct access to him/her to keep him/her properly informed on compliance and safety matters. The nominated person or persons shall be able to demonstrate relevant knowledge, background and satisfactory experience related to aircraft or component maintenance and demonstrate a working knowledge of this Regulation. The organisation shall establish and maintain a maintenance organisation exposition (MOE). Under 145.A.70(a)(12), the MOE shall include, directly or by reference, the procedures specifying how the organisation ensures compliance with Annex II (Part-145). The initial issue of the MOE shall be approved by the competent authority. It shall be amended as necessary so that it remains an up-to-date description of the organisation.
What EASA says
Current Part-145 rule text uses the management system and maintenance procedures framework rather than a simple QA/QC label.
Under 145.A.200, the organisation shall establish, implement and maintain a management system that includes:
- (1) clearly defined accountability and lines of responsibility throughout the organisation, including a direct safety accountability of the accountable manager;
- (2) a description of the overall philosophies and principles of the organisation with regard to safety (‘the safety policy’), and the related safety objectives;
- (3) the identification of aviation safety hazards entailed by the activities of the organisation, their evaluation and the management of the associated risks, including taking actions to mitigate the risks and verify their effectiveness;
- (4) maintaining personnel trained and competent to perform their tasks;
- (5) documentation of all management system key processes, including a process for making personnel aware of their responsibilities and the procedure for amending that documentation;
- (6) a function to monitor the compliance of the organisation with the relevant requirements. Compliance monitoring shall include a feedback system of findings to the accountable manager to ensure the effective implementation of corrective actions as necessary.
The management system shall correspond to the size of the organisation and the nature and complexity of its activities, taking into account the hazards and the associated risks inherent in those activities. If the organisation holds one or more additional organisation certificates within the scope of Regulation (EU) 2018/1139, the management system may be integrated with that required under the additional certificate(s) held.
Under 145.A.202, as part of its management system, the organisation shall establish an internal safety reporting scheme to enable the collection and evaluation of such occurrences that are to be reported under point 145.A.60. The scheme shall also enable the collection and evaluation of those errors, near misses and hazards reported internally that do not fall under that occurrence-reporting requirement. Through that scheme, the organisation shall identify the causes of, and contributing factors to, the errors, near misses and hazards reported, and address them as part of its safety risk management process in accordance with point 145.A.200(a)(3); and ensure an evaluation of all known, relevant information relating to errors, near misses, hazards and the inability to follow procedures, and a method to circulate the information as necessary. The organisation shall make arrangements to ensure the collection of safety issues related to subcontracted activities.
145.A.65 requires maintenance procedures that incorporate human factors and good maintenance practices.
Those clauses create the formal process-control side of what industry normally calls QA.
Output checks, inspections, testing, and release-to-service controls then sit across the maintenance data, performance, and certification clauses.
Common mistakes
The most common mistake is using QA and QC as if they were interchangeable. They are not. If the organisation only checks finished work and never tests whether the system itself is compliant and effective, it has a QC function but not a full process assurance function.
Another mistake is relying on QC alone to satisfy regulatory oversight expectations. A compliant Part-145 maintenance organisation must show that it controls its people, data, procedures, records, hazards, and corrective action system, not only that it occasionally catches errors before release.