After receiving a findings notification under 145.B.350, the organisation must identify the root causes and contributing factors, define a corrective action plan and demonstrate implementation to the competent authority’s satisfaction, within the period agreed with that authority under 145.B.350.
Organisation response and how findings are classified
The organisation’s compliance procedures and management-system feedback must support its response to findings.
Corrective action should resolve the non-compliance and its identified root causes and contributing factors, rather than relying on a reminder or retraining without that investigation.
Classification is in Section B, 145.B.350. A level 1 finding concerns significant non-compliance with the applicable requirements of Regulation (EU) 2018/1139 and its delegated and implementing acts, with the organisation’s procedures and manuals, or with its certificate including the terms of approval, which lowers safety or seriously endangers flight safety.
Level 1 also includes: failure to grant the authority access to the organisation’s facilities referred to in 145.A.140 during normal operating hours after two written requests; obtaining or maintaining the certificate by falsified documentary evidence; evidence of malpractice or fraudulent certificate use; and absence of an accountable manager.
A level 2 finding is any detected non-compliance with those applicable requirements, procedures and manuals, or the certificate and its terms of approval, that is not classified as level 1. The level 2 definition does not contain a separate test of a possible hazard to flight safety.
Written notice, timing and enforcement
A finding detected through oversight or any other means must be communicated in writing, with corrective action requested. If a level 1 finding directly concerns an aircraft, the authority must inform the authority of the Member State in which the aircraft is registered. An authority overseeing an organisation certified by another Member State or EASA must notify that certifying authority of identified non-compliance and indicate its level.
For level 1, the authority must take immediate and appropriate action to prohibit or limit the organisation’s activities. Where appropriate, it must revoke, limit or suspend the certificate in whole or in part, depending on the finding’s extent, until successful corrective action is taken. The organisation’s actions under 145.A.95 remain subject to the applicable agreed period; this is not a single immediate completion deadline.
For level 2, the initial corrective-action implementation period must suit the finding and must not exceed three months. It starts on the date of the written communication requesting corrective action. At its end, the authority may extend the three-month period, subject to the finding’s nature, provided a corrective action plan has been agreed. The authority must assess the proposed corrective action and implementation plans and accept them if sufficient.
If the organisation fails to submit an acceptable plan or perform the corrective action within the accepted or extended period, the finding must be raised to level 1 and the level 1 action taken. The authority records the findings, applicable enforcement, corrective actions and closure dates.
Separately, 145.B.355 requires suspension where there are reasonable grounds that it is necessary to prevent a credible threat to aircraft safety; the certificate action required under 145.B.350; and whole or partial suspension or limitation where unforeseeable circumstances outside the authority’s control prevent the prescribed oversight. Continued validity of the certificate remains conditional under 145.A.90, and surrender or revocation requires return of the certificate without delay.
Observations are a different route
Where a level 1 or level 2 finding is not required, the authority may issue an observation for ineffective performance, a potential future non-compliance, or a suggestion or improvement relevant to overall safety performance. Observations are communicated in writing and recorded by the authority. Under 145.A.95(c), the organisation must give them due consideration and record its decisions; they are not automatically corrective-action findings.
When these rules apply
145.A.95 and 145.B.350 have applied in their current form since 2 December 2022 (Commission Implementing Regulation (EU) 2021/1963).
Part 145 Training
Ready to master Part 145 compliance?
Go beyond the regulation text. Sofema's Part 145 course covers practical compliance strategies, quality system obligations, and real audit scenarios.
View Part 145 course