Press the slash key anywhere on the page to jump to search. Use the arrow keys to move through results and Enter to open one.

145.A.30 — Personnel requirements

On this page
Regulation section

145.A.30 establishes requirements for the accountable manager, nominated persons, a maintenance man-hour plan for qualified staff and competency controls, together with distinct requirements for specialist staff, certifying and support staff and airworthiness review staff, and express derogations.

The accountable manager

Under 145.A.30(a), the organisation shall appoint an accountable manager that has corporate authority to ensure that all maintenance activities of the organisation can be financed and carried out in accordance with Regulation (EU) 2018/1139 and its delegated and implementing acts. The accountable manager shall ensure that all necessary resources are available to accomplish maintenance in accordance with Annex II (Part-145), Annex I (Part-M) and Annex Vb (Part-ML), as applicable, to support the organisation certificate; establish and promote the safety policy specified in 145.A.200(a)(2); and demonstrate a basic understanding of Regulation (EU) No 1321/2014.

As amended by Regulation (EU) 2021/1963, the accountable manager must also establish and promote the safety policy specified in 145.A.200(a)(2). The management system and the accountable manager role are now formally linked.

145.A.200(a)(1) establishes a direct safety accountability of the accountable manager. The persons nominated under 145.A.30(b), (c) and (ca) have their own responsibilities, with a responsibility to, and direct access to, the accountable manager under 145.A.30(cb). Nomination does not remove that accountability.

Nominated persons

The accountable manager nominates a person or group of persons for each of the responsibilities in 145.A.30(b) (maintenance management), 145.A.30(c) (compliance monitoring) and 145.A.30(ca) (effective safety management processes). The maintenance management procedures identify who deputises in the case of lengthy absence. Each of these nomination points expressly permits a person or a group of persons. 145.A.30(cc) requires the nominated persons to have relevant knowledge, background, satisfactory maintenance experience and a working knowledge of the Regulation.

Under 145.A.30(cb), all persons nominated under 145.A.30(b), (c) and (ca) have a responsibility to, and direct access to, the accountable manager to keep that manager properly informed on compliance and safety matters.

Staffing and the maintenance man-hour plan

Under 145.A.30(d), a maintenance man-hour plan ensures sufficient appropriately qualified staff to plan, perform, supervise, inspect and monitor the approved activities. A procedure must reassess the intended work whenever actual staff availability is reduced against the planned staffing for a work shift or period. The production planning duty in 145.A.47 also addresses human performance limitations, including fatigue.

The express trigger in 145.A.30(d) is a reduction in actual staff availability against the planned staffing for a work shift or period, and the response is to reassess the work intended. The rule does not require only increasing staffing; adjusting the planned work through the required process remains a lawful response.

Competency of personnel

145.A.30(e) requires the organisation to establish and control the competency of personnel involved in maintenance, airworthiness reviews, safety management and compliance monitoring, using a procedure and standard agreed with the competent authority. Beyond job expertise, competency includes an understanding of the application of safety management principles, including human factors and human performance, appropriate to the person's function and responsibilities.

The full competency scope of 145.A.30(e) and the procedure and standard agreed with the competent authority apply, including human performance as well as human factors and safety management. Airworthiness review, safety management and compliance monitoring personnel are not left out because they do not personally perform maintenance.

Specialist and airworthiness review staff

Under 145.A.30(f), relevant non-destructive testing staff must meet the recognised European or equivalent standard, and staff carrying out other specialised tasks must meet officially recognised standards. An express derogation for colour contrast dye penetrant tests covers the personnel referred to in 145.A.30(g) and (h) who are qualified in category B1, B3 or L.

If the organisation performs airworthiness reviews under Part-ML and issues the related airworthiness review certificate (ARC), 145.A.30(k) requires staff qualified and authorised under 145.A.37.

Certifying staff and support staff

(g) Any organisation maintaining aircraft, except where stated otherwise in point (j), shall in the case of aircraft line maintenance, have appropriate aircraft-rated certifying staff qualified as category B1, B2, B2L, B3 and L, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35. In addition such organisations may also use appropriately task-trained certifying staff holding the privileges set out in points 66.A.20(a)(1) and 66.A.20(a)(3)(ii) and qualified in accordance with Annex III (Part-66) and point 145.A.35 to carry out minor scheduled line maintenance and simple defect rectification. The availability of such certifying staff shall not replace the need for category B1, B2, B2L, B3 and L certifying staff, as appropriate.

(h) Any organisation maintaining aircraft, except where stated otherwise in point (j), shall: 1. in the case of base maintenance of complex motor-powered aircraft, have appropriate aircraft-type-rated certifying staff, qualified as category C in accordance with Annex III (Part-66) and point 145.A.35. In addition, the organisation shall have sufficient aircraft-type-rated staff qualified as category B1 and B2, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35 to support the category C certifying staff. (i) Category B1 and B2 support staff shall ensure that all relevant tasks or inspections have been carried out to the required standard before the category C certifying staff issues the certificate of release to service. (ii) The organisation shall maintain a register of any such category B1 and B2 support staff. (iii) The category C certifying staff shall ensure that compliance with point (i) has been met and that all work required by the customer has been accomplished during the particular base maintenance check or work package, and shall also assess the impact of any work not carried out, with a view to either requiring its accomplishment or agreeing with the operator to defer such work to another specified check or time limit. 2. in the case of base maintenance of aircraft other than complex motor-powered aircraft, have one of the following: (i) appropriate aircraft-rated certifying staff, qualified as category B1, B2, B2L, B3 and L, as appropriate, in accordance with Annex III (Part-66) and point 145.A.35; (ii) appropriate aircraft-rated certifying staff, qualified in category C or L5, as applicable, and assisted by support staff, as set out in point 145.A.35(a)(1).

(i) Component certifying staff shall be qualified in accordance with Article 5(6) and point 145.A.35.

145.A.35(d) requires certifying staff and support staff to receive sufficient recurrent training in each two-year period on relevant technologies, organisation procedures and safety management, including human factors. Other authorisation and competency requirements, and the expressly specified exception for unforeseen cases, are set out in 145.A.35.

Derogations under 145.A.30(j)

(j) By way of derogation from points (g) and (h), in relation to the obligation to comply with Annex III (Part-66), the organisation may use certifying staff and support staff that are qualified in accordance with the following provisions: 1. For base maintenance carried out at a location outside a territory for which a Member State is responsible under the Chicago Convention, the certifying staff and support staff may be qualified in accordance with the national aviation regulations of the State in which the base maintenance facility is located, subject to the conditions specified in Appendix IV to this Annex. 2. For line maintenance carried out at a line station located outside a territory for which a Member State is responsible under the Chicago Convention, the certifying staff may be qualified, subject to the conditions specified in Appendix IV to this Annex, in accordance with the following alternative conditions: — national aviation regulations of the State in which the line station is located, — national aviation regulations of the State in which the organisation’s principal place of business is located. 3. For a repetitive pre-flight airworthiness directive which specifically states that the flight crew may carry out such airworthiness directive, the organisation may issue a limited certification authorisation to the pilot on the basis of the flight crew licence held. In that case, the organisation shall ensure that the pilot has carried out sufficient practical training ensuring that the pilot can accomplish the airworthiness directive. 4. If an aircraft is operated away from a supported location, the organisation may issue a limited certification authorisation to the pilot on the basis of the flight crew licence held, subject to being satisfied that the pilot has carried out sufficient practical training ensuring that the pilot can accomplish the specified task.

5. In the following unforeseen cases, where an aircraft is grounded at a location other than the main base where no appropriate certifying staff are available, the organisation contracted to provide maintenance support may issue a one-off certification authorisation: (i) to one of its employees holding equivalent type authorisations on aircraft of similar technology, construction and systems; or (ii) to any person with not less than five years maintenance experience and holding a valid ICAO aircraft maintenance licence rated for the aircraft type requiring certification provided there is no organisation appropriately approved under this Part at that location and the contracted organisation obtains and holds on file evidence of the experience and the licence of that person. All such cases as specified in this point must be reported to the competent authority within seven days after issuing such certification authorisation. The organisation issuing the one-off authorisation shall ensure that any such maintenance that could affect flight safety is re-checked by an appropriately approved organisation.

When these requirements apply

The 145.A.30 management, competency and man-hour provisions have applied since 2 December 2022 under Commission Implementing Regulation (EU) 2021/1963. The current 145.A.30(h)(2)(ii) alternative (category C or L5 certifying staff) has applied since 13 February 2026 under Commission Implementing Regulation (EU) 2025/111. Other paragraphs of 145.A.30 have their own application dates.

Part 145 Training

Ready to master Part 145 compliance?

Go beyond the regulation text. Sofema's Part 145 course covers practical compliance strategies, quality system obligations, and real audit scenarios.

View Part 145 course

Sources

Next step Sofema Aviation Academy

Courses for 145.A.30

EASA Part 145 Safety (SMS) & Human Factors (HF) Training (Initial) with VO

2.5 days · Voice Over

Why: names 145.A.30 in its course description.

View course

Related training, not a regulatory requirement. Check course scope and prerequisites before enrolling.

A different role or training goal? Course Finder

Educational reference, not legal advice. Verify against the current Official Journal text linked under Sources. How this hub is made.