Introduction
Under EASA Part 145.A.40(b) and AMC1 145.A.40(b), when a tool manufacturer provides no calibration specifications, the Part 145 organization assumes full responsibility for establishing, justifying, and controlling its own calibration program within its Maintenance Organization Exposition (MOE).
Regulatory & Governance Requirements
- MOE Documentation: Section 2.4 (Equipment and Tools) must formally document the internal calibration policy, risk assessment matrix, decision rules, criteria for Calibrate Before Use (CBU) status, and protocol for adjusting intervals.
- Metrological Traceability: All internal and third-party calibrations must maintain traceability to national or international measurement standards, such as those provided by an ISO/IEC 17025 accredited facility.
- Interval Optimization: Calibration history must be actively tracked. Consecutive cycles demonstrating high stability justify interval extensions, while tools showing measurement drift require shortened intervals or retirement.
Tooling Risk Assessment Criteria
Task Criticality
- High Airworthiness Risk: Measurements affecting primary airframe structures, flight control rigs, engine turbine clearances, or critical joint torque limits. An out-of-tolerance (OOT) tool directly threatens structural integrity and flight safety.
- Low Airworthiness Risk: Non-critical dimensions, cabin interiors, or general troubleshooting measurements where secondary verifications exist or errors do not impact airworthiness.
Vulnerability & Operating Context
- Physical Robustness: Mechanical tools with internal springs suffer fatigue from use, whereas digital instruments hold calibration longer but remain vulnerable to drop shock.
- Environment: Harsh line-maintenance conditions, weather extremes, and fluid contamination accelerate wear compared to controlled workshop environments.
- Usage Frequency: Daily heavy usage justifies cycle-based intervals, whereas idle tools face unmonitored damage or static degradation during storage.
- Historical Drift: Analysis of past calibration certificates determines measurement drift relative to tolerances.
Calibration Interval Strategies
- Fixed Periodic or Usage-Based Intervals: Standardized calendar baselines (e.g., 6 to 12 months) or duty-cycle counts (e.g., 1,000 cycles) applied to high-use tools like torque wrenches and multimeters.
- Calibrate Before Use (CBU): Recommended for low-frequency, idle, or specialized tools. Equipment remains tagged/quarantined and is calibrated immediately prior to task execution to prevent valid calibration time from expiring during storage.
- Pre-Use Operational Verification: Mandatory daily zero-point checks or check-block tests implemented between formal calibrations to catch immediate damage or drift.
Out-of-Tolerance (OOT) & SMS Integration
- Retrospective Impact Study: When a tool fails re-calibration, an immediate safety impact assessment must determine whether aircraft or components released since the last valid calibration require re-inspection.
- SMS Feedback Loop: OOT events must feed directly into the organization's Safety Management System (SMS) to evaluate broader operational airworthiness risks and initiate necessary corrective actions.